Tankless water heater not working? Common causes and fixes
Tankless water heaters only fire when enough water flows through them, so a low-flow fixture, a clogged inlet filter or aerator, or too many taps at once can stop them heating or cause cold bursts. Mineral scale in the heat exchanger is a frequent cause in hard-water areas and is fixed by descaling (flushing). Gas models also need full gas supply and clear venting. The display usually shows an error code: look it up in your manual.
Most likely causes
| # | Likely cause | How common | DIY? |
|---|---|---|---|
| 1 | Error code on the display | Very common | Easy |
| 2 | Flow rate too low | Common | Easy |
| 3 | Clogged inlet water filter | Common | Moderate |
| 4 | Scale build-up | Common with hard water | Moderate |
| 5 | Demand too high | Common | Easy |
| 6 | Gas supply or venting problem | Less common | Call a pro |
1Error code on the display
Tankless units show a code for ignition, flame, venting, overheating or scale problems.
How to check: Note the code and look it up in the manual or on the manufacturer's site.
Fix: Follow the manufacturer's steps for that code.
2Flow rate too low
Each unit has a minimum flow rate to fire. Low-flow fixtures or a partly open tap may be below it.
How to check: Does it heat when you open the hot tap fully?
Fix: Open the tap more, and clean faucet aerators.
3Clogged inlet water filter
A small screen at the cold inlet catches debris.
How to check: Check the manual for its location (usually at the cold inlet).
Fix: Turn off the water, remove and rinse the filter.
4Scale build-up
Minerals build up in the heat exchanger, causing overheating, errors and reduced flow.
How to check: A scale or maintenance code, or reduced hot water flow.
Fix: Descale through the service valves following the manufacturer's instructions, often yearly in hard water.
5Demand too high
Too many showers or appliances at once exceed the unit's capacity.
How to check: Hot water drops when a second tap or appliance runs.
Fix: Spread out use, or have a plumber check sizing.
6Gas supply or venting problem
Undersized gas lines, a closed valve or a blocked vent cause ignition failures.
How to check: Ignition or flame failure codes.
Fix: Check the gas valve is open and the vent terminal outside isn't blocked. Call a technician for gas line or venting issues.
Step-by-step diagnosis
- Note any error code and look it up.
- Open one hot tap fully to check the flow is high enough.
- Clean the inlet filter and faucet aerators.
- Check the gas valve and outdoor vent.
- Descale if you have hard water or a scale code.
- Call a technician for ignition, gas or venting faults.
When to call a professional
Call a plumber or the manufacturer's service for ignition, flame, gas supply, venting or control faults, or if descaling isn't something you want to do yourself.
Questions
Why does my tankless water heater go cold in the shower?
Often because the flow drops below the minimum to keep it firing, or too many taps are running. Scale and gas supply problems can also cause it.
How often should a tankless water heater be flushed?
Many manufacturers recommend descaling yearly, more often in hard water. Check your manual.
How do I reset a tankless water heater?
Many can be reset by turning power off and on at the unit, or with a button on the controller. Repeated resets for the same code mean it needs fixing.
Related guides
These guides are general information. Models differ, so check your owner's manual and the manufacturer's instructions, and follow the safety steps above.