Furnace blowing cold air? Causes and fixes
First check the thermostat: if the fan is set to On instead of Auto, the blower runs even when the furnace isn't heating, so you feel cool air between cycles. Next check the filter, because a clogged filter can overheat the furnace and trip the high-limit switch, shutting off the burners while the fan keeps running. Other common causes are a dirty flame sensor, a failed igniter or pilot, the gas being off, or a blocked condensate drain on a high-efficiency furnace.
Most likely causes
| # | Likely cause | How common | DIY? |
|---|---|---|---|
| 1 | Thermostat fan set to On | Very common | Easy |
| 2 | Dirty air filter (overheating) | Very common | Easy |
| 3 | Dirty flame sensor | Common | Call a pro |
| 4 | Igniter or pilot failure | Common | Call a pro |
| 5 | Gas supply off | Occasional | Easy |
| 6 | Blocked condensate drain (high-efficiency furnaces) | Common in winter | Moderate |
1Thermostat fan set to On
With the fan on On, the blower runs all the time, including when the burners are off.
How to check: Check the thermostat fan setting.
Fix: Set the fan to Auto and the mode to Heat, above room temperature.
2Dirty air filter (overheating)
A clogged filter overheats the heat exchanger. The high-limit switch shuts off the burners and the fan blows cool air.
How to check: Pull the filter and look at it.
Fix: Replace it. Change it regularly during the heating season.
3Dirty flame sensor
The flame sensor proves the burners lit. If it's dirty, the furnace shuts the gas off after a few seconds.
How to check: Burners light briefly then go out, often several times before the furnace locks out.
Fix: A technician can clean the flame sensor, a quick maintenance job.
4Igniter or pilot failure
Hot surface igniters crack with age; older furnaces have a pilot that can go out.
How to check: No glow or click when the furnace tries to start; the status light may flash a code.
Fix: Have the igniter replaced or the pilot serviced.
5Gas supply off
The gas valve to the furnace may be closed or the gas service interrupted.
How to check: Check the gas valve on the line to the furnace is open and that other gas appliances work.
Fix: Open the valve. If gas service is off, call your utility.
6Blocked condensate drain (high-efficiency furnaces)
High-efficiency furnaces make water; if the drain or trap clogs or freezes, a safety switch stops the burners.
How to check: Water around the furnace, or a clogged trap or tube.
Fix: Clear the drain line, or have a technician do it.
Step-by-step diagnosis
- Set the thermostat to Heat and the fan to Auto, and replace batteries if needed.
- Replace the air filter.
- Check the furnace switch (like a light switch near the unit) and breaker are on, and the front panel is closed tightly (an open panel stops it).
- Check the gas valve is open.
- Look at the status light and count the flashes: your manual or the panel label lists the codes.
- Call a technician for flame sensor, igniter, gas valve or repeated lockouts.
When to call a professional
Call an HVAC technician for flame sensor, igniter, gas valve, control board or heat exchanger problems. Every gas furnace should have a working carbon monoxide alarm nearby, and an annual inspection helps prevent breakdowns.
Questions
Why is my furnace running but blowing cold air?
Often because the fan is set to On, the filter is clogged, or the burners are shutting off due to a dirty flame sensor.
How do I reset my furnace?
Turn the furnace switch or breaker off for about 30 seconds and on again. If it keeps locking out, call a technician rather than resetting it repeatedly.
Can a dirty filter make a furnace blow cold air?
Yes: a clogged filter can make the furnace overheat, which trips a safety switch that shuts off the burners while the fan keeps running.
Related guides
These guides are general information. Models differ, so check your owner's manual and the manufacturer's instructions, and follow the safety steps above.