AC not turning on? How to get your air conditioner running

Quick answer

If the AC won't come on at all, check the thermostat first (Cool mode, setpoint below room temperature, batteries), then the breakers for both the indoor unit and the outdoor unit, and the disconnect box next to the outdoor unit. A full condensate pan can trip a float switch that shuts the system off. If the indoor fan runs but the outdoor unit doesn't, a failed capacitor or contactor is a common cause, and that needs a technician.

Safety first: Switch the system off at the thermostat and turn off power at the breaker or the switch on the furnace or air handler before opening any panel. The outdoor unit has its own disconnect box. If a carbon monoxide alarm sounds or you smell gas, leave the house and call 911 or your gas utility.

Most likely causes

#Likely causeHow commonDIY?
1Thermostat settings or powerVery commonEasy
2Tripped breakerCommonEasy
3Outdoor disconnect offCommonEasy
4Condensate float switch trippedCommonModerate
5Capacitor or contactor failedCommonCall a pro
Rather not do it yourself?Describe the problem and get a quote from a local air conditioner repair technician. Free, no obligation.
Get a repair quote

1Thermostat settings or power

Very common · Easy

Wrong mode, a schedule, dead batteries, or a smart thermostat without power.

How to check: Set Cool and a setpoint a few degrees below room temperature; check the screen is on.

Fix: Fix the settings or replace the batteries.

2Tripped breaker

Common · Easy

Central AC has separate breakers for the indoor air handler or furnace and the outdoor unit.

How to check: Look in the panel for tripped breakers.

Fix: Reset once. If it trips again, call a technician: repeated trips point to an electrical or compressor fault.

3Outdoor disconnect off

Common · Easy

The box on the wall by the outdoor unit has a pull-out block or switch.

How to check: Check it's on or the block is inserted the right way.

Fix: Turn it on.

4Condensate float switch tripped

Common · Moderate

A clogged drain fills the pan, and a float switch shuts the AC off to prevent a flood.

How to check: Water in the drain pan or a full condensate pump.

Fix: Clear the drain line (see our AC leaking guide). The AC restarts when the pan drains.

5Capacitor or contactor failed

Common · Call a pro

These parts start the outdoor compressor and fan.

How to check: Indoor fan runs but the outdoor unit is silent or humming.

Fix: Call a technician. Capacitors hold a dangerous charge even with the power off.

Step-by-step diagnosis

  1. Check the thermostat.
  2. Check both AC breakers.
  3. Check the outdoor disconnect.
  4. Check for water in the drain pan and clear the drain.
  5. Wait 5 minutes after resetting power; many systems have a delay before restarting.
  6. Call a technician if the outdoor unit hums or won't start.

When to call a professional

Call an HVAC technician for capacitor, contactor, motor, compressor or wiring faults, or if a breaker trips again.

Rather not do it yourself?Describe the problem and get a quote from a local air conditioner repair technician. Free, no obligation.
Get a repair quote

Questions

Why won't my AC turn on after a power outage?

A breaker may have tripped, or the system may be waiting through its restart delay. Some thermostats need resetting after an outage.

Is there a reset button on an AC unit?

Some outdoor units have one, but most don't. Resetting the breaker or disconnect has the same effect. Repeated resets can damage the compressor if there's a fault.

Why does my AC fan run but not the outside unit?

A failed capacitor or contactor, a tripped outdoor breaker or the disconnect being off.