AC not turning on? How to get your air conditioner running
If the AC won't come on at all, check the thermostat first (Cool mode, setpoint below room temperature, batteries), then the breakers for both the indoor unit and the outdoor unit, and the disconnect box next to the outdoor unit. A full condensate pan can trip a float switch that shuts the system off. If the indoor fan runs but the outdoor unit doesn't, a failed capacitor or contactor is a common cause, and that needs a technician.
Most likely causes
| # | Likely cause | How common | DIY? |
|---|---|---|---|
| 1 | Thermostat settings or power | Very common | Easy |
| 2 | Tripped breaker | Common | Easy |
| 3 | Outdoor disconnect off | Common | Easy |
| 4 | Condensate float switch tripped | Common | Moderate |
| 5 | Capacitor or contactor failed | Common | Call a pro |
1Thermostat settings or power
Wrong mode, a schedule, dead batteries, or a smart thermostat without power.
How to check: Set Cool and a setpoint a few degrees below room temperature; check the screen is on.
Fix: Fix the settings or replace the batteries.
2Tripped breaker
Central AC has separate breakers for the indoor air handler or furnace and the outdoor unit.
How to check: Look in the panel for tripped breakers.
Fix: Reset once. If it trips again, call a technician: repeated trips point to an electrical or compressor fault.
3Outdoor disconnect off
The box on the wall by the outdoor unit has a pull-out block or switch.
How to check: Check it's on or the block is inserted the right way.
Fix: Turn it on.
4Condensate float switch tripped
A clogged drain fills the pan, and a float switch shuts the AC off to prevent a flood.
How to check: Water in the drain pan or a full condensate pump.
Fix: Clear the drain line (see our AC leaking guide). The AC restarts when the pan drains.
5Capacitor or contactor failed
These parts start the outdoor compressor and fan.
How to check: Indoor fan runs but the outdoor unit is silent or humming.
Fix: Call a technician. Capacitors hold a dangerous charge even with the power off.
Step-by-step diagnosis
- Check the thermostat.
- Check both AC breakers.
- Check the outdoor disconnect.
- Check for water in the drain pan and clear the drain.
- Wait 5 minutes after resetting power; many systems have a delay before restarting.
- Call a technician if the outdoor unit hums or won't start.
When to call a professional
Call an HVAC technician for capacitor, contactor, motor, compressor or wiring faults, or if a breaker trips again.
Questions
Why won't my AC turn on after a power outage?
A breaker may have tripped, or the system may be waiting through its restart delay. Some thermostats need resetting after an outage.
Is there a reset button on an AC unit?
Some outdoor units have one, but most don't. Resetting the breaker or disconnect has the same effect. Repeated resets can damage the compressor if there's a fault.
Why does my AC fan run but not the outside unit?
A failed capacitor or contactor, a tripped outdoor breaker or the disconnect being off.
Related guides